How to Setup the AccuFIT9000 Fit Testing Machine

[vc_row type=”in_container” full_screen_row_position=”middle” scene_position=”center” text_color=”dark” text_align=”left” overlay_strength=”0.3″ shape_divider_position=”bottom”][vc_column column_padding=”no-extra-padding” column_padding_position=”all” background_color_opacity=”1″ background_hover_color_opacity=”1″ column_link_target=”_self” column_shadow=”none” column_border_radius=”none” width=”1/1″ tablet_width_inherit=”default” tablet_text_alignment=”default” phone_text_alignment=”default” column_border_width=”none” column_border_style=”solid”][vc_video link=”https://www.youtube.com/watch?v=at0VkOubvNs&feature=emb_title” align=”center”][vc_text_separator title=”Video Transcript” i_icon_fontawesome=”fa fa-file-video-o” i_color=”black” add_icon=”true”][vc_column_text]Hi, I’m Wesley with Accutec-IHS. The AccuFIT9000 is a new instrument for performing respirator fit testing which depends on measuring the fit of a tight fitting respirator by comparing the ratio of the respirable particles in the breathing zone, with the concentration of these ultra-fine particles in the ambient atmosphere. This technology is called condensation particulate counting. To learn more, watch the video condensation particulate counting on the AccuFIT9000. 

          Let’s ensure the instrument is working properly, remove the instrument from the carrying case and locate the power supply AC cord, alcohol capsule sample tubing, and HEPA filter. Plug the power supply into an electric outlet. Connect the power supply and plug the connector into the port on the back panel of the AccuFIT9000. Next, remove the alcohol wick assembly from the capsule and place it on a clean surface. Then pour reagent grade isopropyl alcohol which is supplied with the instrument into the capsule so that the level of liquid is above the bottom line and below the top line. Replace the alcohol wick into the capsule and allow the alcohol to saturate the wick. This takes about two minutes. Remove the wick assembly from the capsule and tap off any excessive alcohol. Then remove the storage cap from the AccuFIT9000 alcohol port and replace it with the saturated alcohol wick. The locating pin and camming groove on the cap will guide the wick into its proper location. Now attach the sample tube to the a AccuFIT9000 making sure that you attach the blue tube to the blue inlet and the clear tube to the silver Inlet. Attach the HEPA filter to the clear tube making sure that the arrow showing flow direction is pointing toward the tube. Now press and hold the on/off button on the AccuFIT9000 until it illuminates with a red light. Allow the instrument to complete its warm-up and internal self checks. This takes about a minute and then will automatically transition to the opening screen.  The on/off button will now illuminate green. Touch the administration icon and then select the database icon using the drop down arrow. Highlight demo and then touch the load button. A message should appear telling you that the database demo is successfully loaded into active memory. Please note that the demo database does not allow you to perform all of the functions to test the instrument. It does not allow you to add names, respirators, or protocols to memory, nor does it allow you to save any results obtained. Press exit and then the return arrow on the previous screen. This returns you to the opening screen.

          Now it is time to test the functionality of the AccuFIT9000. Touch the icon labeled validation check, remove the HEPA filter from the clear tube and press start. The AccuFIT9000 will now measure the ambient particles and produce account. The validation check will now ask you to replace the HEPA filter into the clear tube and press next. The validation check will proceed automatically to check that there are no internal leaks in the system, that the switching valve is functioning properly, and that the unit can calculate the max fit factor. You have now demonstrated that the AccuFIT9000 is performing as designed. To shut down the instrument, hold the on/off button until it flashes red and green and touch the yes box. It is very important to remove the alcohol cartridge and replace it with the storage cap. Failure to remove the alcohol cartridge can result in alcohol contamination of the optics. Replace the alcohol cartridge into the   capsule. This ensures that there will be no spillage and that the alcohol cartridge will be ready to use the next time you want to perform fit testing. If the AccuFIT9000 is to be stored in the carrying case, remove the sample tube and power connector, and place the cutouts in the protective foam insert and position the instrument appropriately.[/vc_column_text][/vc_column][/vc_row]

Share this Article

Facebook
Twitter
LinkedIn
AccutFIT9000 Respirator FIt Testing Kit

More Articles

OSHA’s Newest Fast Fit Quantitative Respirator Fit Testing Protocols Can Save You Time and Money

A Guide to Understanding and Optimizing Your Respiratory Protection Program

Practical Respirators: A Complete Guide